Tap Water Lookup

EPA system UTAH18028 · Utah

Sandy City Water System: Lithium at or above EPA's 10 ppb health reference level

System ID UTAH18028; community water system; Utah; source: purchased surface water; serves 99,750 people via 25,816 connections; status: active

In focus99,750people served, EPA registry
Public records. Clearer context.
Highest result against its EPA referenceLithium
Lithium: 11.5 ppb; health reference level 10 ppb. highest single sample.11.5 ppbhealth reference level: 10 ppb

highest single sample; sampled July 2023–July 2025. Source: EPA UCMR 5 final release, August 2026.

Sandy City Water System is a local-government-owned community water system in Utah serving about 99,750 people, matched to 4 ZIP codes.

< 4.0 ppt
PFOA, highest complete-set average
12 samples, none above the reporting level
MCL 4.0 ppt · not detected above the reporting level
< 4.0 ppt
PFOS, highest complete-set average
12 samples, none above the reporting level
MCL 4.0 ppt · not detected above the reporting level
11.5 ppb
Lithium, highest single sample
1 of 12 samples above the reporting level
health reference level 10 ppb · at or above the health reference level
0 / 29
PFAS found above the reporting level
360 results, 8 entry points
0 at or above an MCL on the average basis
2.9 ppb
Lead 90th percentile
period ending Dec 31, 2024
action level 15 ppb · below the action level
1
health-based violation since Sep 3, 2016
134 violations in total

PFAS treatment declared to EPA: None declared (30 of 30 sampling events) · PFAS found before UCMR 5: Yes, at 30 of 30 sampling events

What EPA says about what was found

  • Lithium EPA's health reference level is derived from a 2008 provisional toxicity value based on effects seen at therapeutic lithium doses; EPA notes the assessment is provisional. EPA source

Quoted from EPA assessments. This site adds no health claims of its own.

PFAS and lithium: what EPA's national survey found

EPA tested this water for 30 substances and found 1. Lithium reached 11.5 ppb; EPA's health reference level, which is guidance and not a limit, is 10 ppb.

Between July 2023 and July 2025, EPA's UCMR 5 program tested 360 samples from 8 sampling locations for 30 contaminants (29 PFAS plus lithium). 1 were detected above the reporting level in at least one sample. Lithium reached 11.5 ppb in a single sample, at or above the health reference level of 10 ppb, which is non-regulatory.

Result EPA comparesNot detected, shown at the reporting levelEPA reference value, at the middle of each row's scale
ContaminantResult against the EPA referenceResultStatus
Lithiumhighest single sample
11.5 ppb
at or above the health reference level
Show the 29 contaminants not detected above the reporting level
11Cl-PF3OUdSnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
4:2 FTSnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
6:2 FTSnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
8:2 FTSnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
9Cl-PF3ONSnot detected · reporting level 2.0 ppt
< 2.0 ppt
not detected above the reporting level
ADONAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
HFPO-DA (GenX)not detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
NEtFOSAAnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
NFDHAnot detected · reporting level 20.0 ppt
< 20.0 ppt
not detected above the reporting level
NMeFOSAAnot detected · reporting level 6.0 ppt
< 6.0 ppt
not detected above the reporting level
PFBAnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
PFBSnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFDAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFDoAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFEESAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFHpAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFHpSnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFHxAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFHxSnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFMBAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFMPAnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFNAnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFOAnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFOSnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFPeAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFPeSnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFTAnot detected · reporting level 8.0 ppt
< 8.0 ppt
not detected above the reporting level
PFTrDAnot detected · reporting level 7.0 ppt
< 7.0 ppt
not detected above the reporting level
PFUnAnot detected · reporting level 2.0 ppt
< 2.0 ppt
not detected above the reporting level
Full table: samples, detections, highest single sample, complete-set average and sampling dates for all 30 contaminants
ContaminantSamplesDetectionsHighest single sampleComplete-set average (results used)EPA referenceStatusSampled
Lithium12111.5 ppb2.9 ppb (4 of 4)10 ppb health reference level · compared on the highest sampleat or above the health reference levelJuly 2023 – July 2025
11Cl-PF3OUdS120< 5.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
4:2 FTS120< 3.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
6:2 FTS120< 5.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
8:2 FTS120< 5.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
9Cl-PF3ONS120< 2.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
ADONA120< 3.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
HFPO-DA (GenX)120< 5.0 ppt10.0 ppt MCL (rescission proposed) · compared on the complete-set averagenot detected above the reporting levelJuly 2023 – July 2025
NEtFOSAA120< 5.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
NFDHA120< 20.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
NMeFOSAA120< 6.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFBA120< 5.0 ppt6,000 ppt screening level · compared on the highest samplenot detected above the reporting levelJuly 2023 – July 2025
PFBS120< 3.0 ppt2,000 ppt health-based water concentration · compared on the highest samplenot detected above the reporting levelJuly 2023 – July 2025
PFDA120< 3.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFDoA120< 3.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFEESA120< 3.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFHpA120< 3.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFHpS120< 3.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFHxA120< 3.0 ppt3,000 ppt screening level · compared on the highest samplenot detected above the reporting levelJuly 2023 – July 2025
PFHxS120< 3.0 ppt10.0 ppt MCL (rescission proposed) · compared on the complete-set averagenot detected above the reporting levelJuly 2023 – July 2025
PFMBA120< 3.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFMPA120< 4.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFNA120< 4.0 ppt10.0 ppt MCL (rescission proposed) · compared on the complete-set averagenot detected above the reporting levelJuly 2023 – July 2025
PFOA120< 4.0 ppt4.0 ppt MCL · compared on the complete-set averagenot detected above the reporting levelJuly 2023 – July 2025
PFOS120< 4.0 ppt4.0 ppt MCL · compared on the complete-set averagenot detected above the reporting levelJuly 2023 – July 2025
PFPeA120< 3.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFPeS120< 4.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFTA120< 8.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFTrDA120< 7.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
PFUnA120< 2.0 pptnone setnot detected above the reporting levelJuly 2023 – July 2025
UCMR 5 is a one-time national monitoring survey. Its results do not indicate compliance or non-compliance with the PFAS Maximum Contaminant Levels, which are enforced on running annual averages and take effect in 2029 (EPA has proposed allowing extensions to 2031). A single result above a limit on this page is a measurement, not a violation.

Sampling-point average: mean of a location's two (ground water) or four (surface water) UCMR 5 results with non-detects counted as zero, EPA's method for comparing UCMR 5 data to the PFAS MCLs. EPA rounds to the reference value's significant digits before deciding whether an average is "greater than" an MCL (PFOA/PFOS averages count as above 4.0 ng/L only from 4.05 ng/L; lithium results count as above the 10 ppb reference only from 15 ppb). This site does not apply that rounding: "at or above" here means the measured value is numerically at or above the reference.

Every detection by sampling location (1 results)
DateSampling locationSource waterContaminantResultReporting level
Jan 22, 2024Entry Point to Dist. System Metropolitan Tpsurface waterLithium11.5 ppb9 ppb

Utility-reported context (UCMR 5 questionnaire, aggregated across sampling events): PFAS previously found at this system: yes at 30 of 30 sampling events; potential PFAS sources nearby: no at 20 of 30 sampling events, not known at 10 of 30 sampling events; PFAS treatment in place: no PFAS treatment at 30 of 30 sampling events.

Lead at customer taps

In the latest completed monitoring period, ending Dec 31, 2024, 9 in 10 sampled homes had lead at or below 2.9 ppb, below the 15 ppb action level that triggers utility action. None of the 15 periods on record reached it.

Action level 15 ppb015Jan 1, 1994 – Dec 31, 1994: 13 ppbJan 1, 1995 – Dec 31, 1995: 5 ppbJan 1, 1998 – Dec 31, 2000: 5 ppbJan 1, 2001 – Dec 31, 2003: 4 ppbJan 1, 2002 – Dec 31, 2004: 2 ppbJan 1, 2005 – Dec 31, 2007: 5 ppbJan 1, 2008 – Dec 31, 2010: 3.5 ppbJan 1, 2011 – Dec 31, 2013: 3.2 ppbJan 1, 2014 – Dec 31, 2016: 4.0 ppbJan 1, 2022 – Dec 31, 2022: 2.7 ppbJan 1, 2023 – Dec 31, 2023: 3.1 ppbJan 1, 2024 – Dec 31, 2024: 2.9 ppbDec 31, 1994Dec 31, 20242.9 ppb

In the most recent completed lead monitoring period, ending Dec 31, 2024, the 90th-percentile lead result at customer taps was 2.9 ppb, below the action level of 15 ppb (15 monitoring periods on record, none at the action level). The 90th percentile is the value that 9 in 10 sampled homes were at or below. Values are in parts per billion (ppb).

Monitoring periodMetal90th percentileAction levelStatus
Jan 1, 2024 – Dec 31, 2024Lead2.9 ppb15 ppbbelow the action level
Jan 1, 2023 – Dec 31, 2023Lead3.1 ppb15 ppbbelow the action level
Jan 1, 2022 – Dec 31, 2022Lead2.7 ppb15 ppbbelow the action level
Jan 1, 2014 – Dec 31, 2016Lead4.0 ppb15 ppbbelow the action level
Jan 1, 2011 – Dec 31, 2013Lead3.2 ppb15 ppbbelow the action level
Jan 1, 2008 – Dec 31, 2010Lead3.5 ppb15 ppbbelow the action level
Jan 1, 2005 – Dec 31, 2007Lead5 ppb15 ppbbelow the action level
Jan 1, 2002 – Dec 31, 2004Lead2 ppb15 ppbbelow the action level
Jan 1, 2001 – Dec 31, 2003Lead4 ppb15 ppbbelow the action level
Jan 1, 1998 – Dec 31, 2000Lead5 ppb15 ppbbelow the action level
Jan 1, 1995 – Dec 31, 1995Lead5 ppb15 ppbbelow the action level
Jan 1, 1994 – Dec 31, 1994Lead13 ppb15 ppbbelow the action level
Show all 15 monitoring periods on record
Monitoring periodMetal90th percentileAction levelStatus
Jan 1, 2024 – Dec 31, 2024Lead2.9 ppb15 ppbbelow the action level
Jan 1, 2023 – Dec 31, 2023Lead3.1 ppb15 ppbbelow the action level
Jan 1, 2022 – Dec 31, 2022Lead2.7 ppb15 ppbbelow the action level
Jan 1, 2014 – Dec 31, 2016Lead4.0 ppb15 ppbbelow the action level
Jan 1, 2011 – Dec 31, 2013Lead3.2 ppb15 ppbbelow the action level
Jan 1, 2008 – Dec 31, 2010Lead3.5 ppb15 ppbbelow the action level
Jan 1, 2005 – Dec 31, 2007Lead5 ppb15 ppbbelow the action level
Jan 1, 2002 – Dec 31, 2004Lead2 ppb15 ppbbelow the action level
Jan 1, 2001 – Dec 31, 2003Lead4 ppb15 ppbbelow the action level
Jan 1, 1998 – Dec 31, 2000Lead5 ppb15 ppbbelow the action level
Jan 1, 1995 – Dec 31, 1995Lead5 ppb15 ppbbelow the action level
Jan 1, 1994 – Dec 31, 1994Lead13 ppb15 ppbbelow the action level
Jan 1, 1993 – Dec 31, 1993Lead8 ppb15 ppbbelow the action level
Jul 1, 1992 – Dec 31, 1992Lead5 ppb15 ppbbelow the action level
Jan 1, 1992 – Jun 30, 1992Lead5 ppb15 ppbbelow the action level

Drinking water violations since Sep 3, 2016

EPA lists 134 violations since Sep 3, 2016. 1 is health-based, meaning a contaminant or treatment rule was not met. The other 133 concern missed monitoring, reporting or public notices.

EPA's SDWIS database lists 134 violations recorded since Sep 3, 2016: 1 health-based (a contaminant above its maximum contaminant level, a disinfectant above its maximum residual level, or a required treatment technique not met), 131 for monitoring or reporting, 2 other (public notification or consumer confidence report requirements).

Compliance periodTypeContaminant / ruleDescriptionRecordsStatus
Feb 8, 2019 – Mar 15, 2019MCL · health-basedFluoride (104 MG/L, limit 4.0 mg/L)Maximum Contaminant Level Violation, Single Sample1 recordResolved · 4 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRDichloromethaneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRO-DichlorobenzeneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRP-DichlorobenzeneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRVinyl ChlorideMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRTrans-1,2-DichloroethyleneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MR1,2-DichloroethaneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRCarbon TetrachlorideMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRTrichloroethyleneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRChlorobenzeneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRBenzeneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MREthylbenzeneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MR1,2,4-TrichlorobenzeneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MR1,1-DichloroethyleneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRNitrateMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRXylenes, TotalMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MR1,1,1-TrichloroethaneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MR1,2-DichloropropaneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRTolueneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRCis-1,2-DichloroethyleneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRTetrachloroethyleneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MRStyreneMonitoring, Regular1 recordResolved · 3 enforcement actions
Jan 1, 2023 – Dec 31, 2023MR1,1,2-TrichloroethaneMonitoring, Regular1 recordResolved · 3 enforcement actions
Feb 14, 2019OtherPublic NoticePublic Notification Violation for NPDWR Violation1 recordResolved · 3 enforcement actions
Jul 1, 2018OtherConsumer Confidence RuleConsumer Confidence Report Complete Failure to Report1 recordResolved · 2 enforcement actions
Show the remaining 109 violation records
Compliance periodTypeContaminant / ruleDescriptionRecordsStatus
Jan 1, 2018 – Mar 31, 2018MR1,2,4-TrichlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRCis-1,2-DichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRXylenes, TotalMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRDichloromethaneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRO-DichlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRP-DichlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRVinyl ChlorideMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRTrans-1,2-DichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MR1,2-DichloroethaneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRCarbon TetrachlorideMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MR1,2-DichloropropaneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MR1,1,2-TrichloroethaneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRChlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MREthylbenzeneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRStyreneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRTolueneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MR1,1,1-TrichloroethaneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MR1,1-DichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRTrichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRTetrachloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2018 – Mar 31, 2018MRBenzeneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MR1,2,4-TrichlorobenzeneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRCis-1,2-DichloroethyleneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRDichloromethaneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRP-DichlorobenzeneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRVinyl ChlorideMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MR1,1-DichloroethyleneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MR1,2-DichloroethaneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRCarbon TetrachlorideMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MR1,2-DichloropropaneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRTrichloroethyleneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MR1,1,2-TrichloroethaneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRTetrachloroethyleneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRBenzeneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRTolueneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MREthylbenzeneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRTrans-1,2-DichloroethyleneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRStyreneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MR1,1,1-TrichloroethaneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRO-DichlorobenzeneMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRXylenes, TotalMonitoring, Regular1 recordResolved
Apr 1, 2017 – Jun 30, 2017MRChlorobenzeneMonitoring, Regular1 recordResolved
Feb 1, 2017 – Feb 28, 2017MONRevised Total Coliform RuleMonitoring, Routine (RTCR)1 recordResolved
Jan 1, 2017 – Mar 31, 2017MR1,2,4-TrichlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRCis-1,2-DichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRXylenes, TotalMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRDichloromethaneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRO-DichlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRVinyl ChlorideMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MR1,1-DichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRTrichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRTetrachloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRTolueneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MREthylbenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRBhc-GammaMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRMethoxychlorMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MROxamylMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRSimazineMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRPicloramMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRHeptachlorMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRHeptachlor EpoxideMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MR2,4-DMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MR2,4,5-TpMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRBenzo(A)pyreneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRPentachlorophenolMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRTotal Polychlorinated Biphenyls (Pcb)Monitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MR1,2,4-TrichlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRXylenes, TotalMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRO-DichlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRP-DichlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRVinyl ChlorideMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRTrans-1,2-DichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MR1,2-DichloroethaneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRCarbon TetrachlorideMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MR1,1,2-TrichloroethaneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRTetrachloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRChlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRDichloromethaneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRBenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MR1,2-DichloropropaneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MR1,1,1-TrichloroethaneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRCarbofuranMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MREthylbenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRBenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRTrans-1,2-DichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRChlordaneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRTolueneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRStyreneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRLassoMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRTrichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRDinosebMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRAtrazineMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRChlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MR1,1-DichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRCarbon TetrachlorideMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MR1,2-DichloropropaneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRHexachlorocyclopentadieneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRHexachlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MRP-DichlorobenzeneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRToxapheneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRStyreneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRDi(2-Ethylhexyl) PhthalateMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRCis-1,2-DichloroethyleneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MR1,1,1-TrichloroethaneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRDi(2-Ethylhexyl) AdipateMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MREndrinMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MR1,2-DichloroethaneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Mar 31, 2017MR1,1,2-TrichloroethaneMonitoring, Regular1 recordResolved
Jan 1, 2017 – Dec 31, 2019MRDalaponMonitoring, Regular1 recordResolved

Sanitary surveys and site visits

Most recent state inspection: Oct 5, 2023 (sanitary survey); 1 visit since Sep 3, 2021.

What you can do about these results

Lithium: what reduces it

Lithium reached 11.5 ppb in a single sample, at or above EPA's non-regulatory 10 ppb health reference level.

No NSF/ANSI certification claim exists for lithium. Reverse osmosis systems reduce dissolved minerals generally; we do not recommend a specific product for lithium.

ZIP codes served

Sources

Data vintage: EPA UCMR 5 occurrence data, samples collected 2023-01-03 – 2026-06-17, final release, August 2026 (file dated Aug 28, 2026); EPA SDWIS via ECHO, 2026Q2 extract (file dated Jul 9, 2026); EPA service-area boundaries v3.0; Census 2020 ZCTAs. Page generated 2026-09-03.

Keep exploring

Every record tells
part of the story.

Find a place. Read the measurements.
Understand the context.