Tap Water Lookup

EPA system PR0003293 · Puerto Rico

Aguadilla: Lithium at or above EPA's 10 ppb health reference level

System ID PR0003293; community water system; Puerto Rico; source: surface water; serves 124,782 people via 46,735 connections; status: active

In focus124,782people served, EPA registry
Public records. Clearer context.
Highest result against its EPA referenceLithium
Lithium: 23.7 ppb; health reference level 10 ppb. highest single sample.23.7 ppbhealth reference level: 10 ppb

highest single sample; sampled January 2023–December 2025. Source: EPA UCMR 5 final release, August 2026.

Aguadilla is a local-government-owned community water system in Puerto Rico serving about 124,782 people, matched to 3 ZIP codes.

< 4.0 ppt
PFOA, highest complete-set average
32 samples, none above the reporting level
MCL 4.0 ppt · not detected above the reporting level
5.2 ppt
PFOS, highest complete-set average
2 of 2 results at the highest location; highest single sample 5.3 ppt
MCL 4.0 ppt · at or above the MCL
23.7 ppb
Lithium, highest single sample
3 of 33 samples above the reporting level
health reference level 10 ppb · at or above the health reference level
5 / 29
PFAS found above the reporting level
953 results, 14 entry points
1 at or above an MCL on the average basis
6 ppb
Lead 90th percentile
period ending Dec 31, 2015
action level 15 ppb · below the action level
34
health-based violations since Sep 3, 2016
108 violations in total

What EPA says about what was found

  • Lithium EPA's health reference level is derived from a 2008 provisional toxicity value based on effects seen at therapeutic lithium doses; EPA notes the assessment is provisional. EPA source
  • PFOS EPA set the health goal (MCLG) for PFOS at zero. EPA's 2024 rule cites its health effects assessment linking PFOS exposure to certain cancers, immune and developmental effects, and changes in cholesterol. EPA source
  • PFBS EPA's 2021 PFBS toxicity assessment cites thyroid, kidney and developmental effects in animal studies. EPA source
  • PFHxA EPA's 2023 IRIS assessment for PFHxA cites developmental, liver and blood effects in animal studies. EPA source

Quoted from EPA assessments. This site adds no health claims of its own.

PFAS and lithium: what EPA's national survey found

EPA tested this water for 30 substances and found 6. PFOS averaged 5.2 ppt where EPA's limit is 4.0 ppt. EPA's limit applies to a running yearly average and is enforced from 2029. That PFOS result is higher than 93% of the 10,307 water systems EPA tested for it. Lithium reached 23.7 ppb; EPA's health reference level, which is guidance and not a limit, is 10 ppb.

Between January 2023 and December 2025, EPA's UCMR 5 program tested 953 samples from 14 sampling locations for 30 contaminants (29 PFAS plus lithium). 6 were detected above the reporting level in at least one sample. Averaged over a complete monitoring set, the highest sampling location for PFOS was 5.2 ppt, at or above the MCL of 4.0 ppt that applies from 2029 (highest single sample 5.3 ppt). Lithium reached 23.7 ppb in a single sample, at or above the health reference level of 10 ppb, which is non-regulatory.

Result EPA comparesNot detected, shown at the reporting levelEPA reference value, at the middle of each row's scale
ContaminantResult against the EPA referenceResultStatus
Lithiumhighest single sample
23.7 ppb
at or above the health reference level
PFPeAhighest single sample
6.7 ppt
detected; no EPA reference value
PFOScomplete-set average
5.2 ppt
at or above the MCL
PFBShighest single sample
5.2 ppt
below the health-based water concentration
PFHxAhighest single sample
4.7 ppt
below the screening level
PFBAhighest single sample
7.8 ppt
below the screening level
Show the 24 contaminants not detected above the reporting level
11Cl-PF3OUdSnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
4:2 FTSnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
6:2 FTSnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
8:2 FTSnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
9Cl-PF3ONSnot detected · reporting level 2.0 ppt
< 2.0 ppt
not detected above the reporting level
ADONAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
HFPO-DA (GenX)not detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
NEtFOSAAnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
NFDHAnot detected · reporting level 20.0 ppt
< 20.0 ppt
not detected above the reporting level
NMeFOSAAnot detected · reporting level 6.0 ppt
< 6.0 ppt
not detected above the reporting level
PFDAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFDoAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFEESAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFHpAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFHpSnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFHxSnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFMBAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFMPAnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFNAnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFOAnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFPeSnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFTAnot detected · reporting level 8.0 ppt
< 8.0 ppt
not detected above the reporting level
PFTrDAnot detected · reporting level 7.0 ppt
< 7.0 ppt
not detected above the reporting level
PFUnAnot detected · reporting level 2.0 ppt
< 2.0 ppt
not detected above the reporting level
Full table: samples, detections, highest single sample, complete-set average and sampling dates for all 30 contaminants
ContaminantSamplesDetectionsHighest single sampleComplete-set average (results used)EPA referenceStatusSampled
Lithium33323.7 ppb11.9 ppb (2 of 2)10 ppb health reference level · compared on the highest sampleat or above the health reference levelJanuary 2023 – December 2025
PFPeA3236.7 ppt3.4 ppt (2 of 2)none setdetected; no EPA reference valueJanuary 2023 – December 2025
PFOS3255.3 ppt5.2 ppt (2 of 2)4.0 ppt MCL · compared on the complete-set averageat or above the MCLJanuary 2023 – December 2025
PFBS3285.2 ppt4.5 ppt (2 of 2)2,000 ppt health-based water concentration · compared on the highest samplebelow the health-based water concentrationJanuary 2023 – December 2025
PFHxA3224.7 ppt2.4 ppt (2 of 2)3,000 ppt screening level · compared on the highest samplebelow the screening levelJanuary 2023 – December 2025
PFBA3227.8 ppt3.9 ppt (2 of 2)6,000 ppt screening level · compared on the highest samplebelow the screening levelJanuary 2023 – December 2025
11Cl-PF3OUdS320< 5.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
4:2 FTS320< 3.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
6:2 FTS320< 5.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
8:2 FTS320< 5.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
9Cl-PF3ONS320< 2.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
ADONA320< 3.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
HFPO-DA (GenX)320< 5.0 ppt10.0 ppt MCL (rescission proposed) · compared on the complete-set averagenot detected above the reporting levelJanuary 2023 – December 2025
NEtFOSAA300< 5.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
NFDHA320< 20.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
NMeFOSAA300< 6.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
PFDA320< 3.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
PFDoA320< 3.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
PFEESA320< 3.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
PFHpA320< 3.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
PFHpS320< 3.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
PFHxS320< 3.0 ppt10.0 ppt MCL (rescission proposed) · compared on the complete-set averagenot detected above the reporting levelJanuary 2023 – December 2025
PFMBA320< 3.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
PFMPA320< 4.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
PFNA320< 4.0 ppt10.0 ppt MCL (rescission proposed) · compared on the complete-set averagenot detected above the reporting levelJanuary 2023 – December 2025
PFOA320< 4.0 ppt4.0 ppt MCL · compared on the complete-set averagenot detected above the reporting levelJanuary 2023 – December 2025
PFPeS320< 4.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
PFTA300< 8.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
PFTrDA300< 7.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
PFUnA320< 2.0 pptnone setnot detected above the reporting levelJanuary 2023 – December 2025
UCMR 5 is a one-time national monitoring survey. Its results do not indicate compliance or non-compliance with the PFAS Maximum Contaminant Levels, which are enforced on running annual averages and take effect in 2029 (EPA has proposed allowing extensions to 2031). A single result above a limit on this page is a measurement, not a violation.

Sampling-point average: mean of a location's two (ground water) or four (surface water) UCMR 5 results with non-detects counted as zero, EPA's method for comparing UCMR 5 data to the PFAS MCLs. EPA rounds to the reference value's significant digits before deciding whether an average is "greater than" an MCL (PFOA/PFOS averages count as above 4.0 ng/L only from 4.05 ng/L; lithium results count as above the 10 ppb reference only from 15 ppb). This site does not apply that rounding: "at or above" here means the measured value is numerically at or above the reference.

Every detection by sampling location (23 results)
DateSampling locationSource waterContaminantResultReporting level
Jan 12, 2023PZ RIO GRANDE I Pz Rio Grande Iground waterPFBS3.1 ppt3.0 ppt
Jan 12, 2023PZ RIO GRANDE I Pz Rio Grande Iground waterPFOS4.9 ppt4.0 ppt
Jan 12, 2023PZ NARANJO SEGUI 2 Pz Naranjo Segui 2ground waterPFOS4.1 ppt4.0 ppt
Jan 12, 2023PZ PUENTE II Pz Puente IIground waterPFBS3.4 ppt3.0 ppt
Jan 12, 2023PZ PUENTE II Pz Puente IIground waterLithium11.5 ppb9 ppb
Jan 13, 2023PZ RINCON I Pz Rincon Iground waterPFBS4.4 ppt3.0 ppt
Jan 13, 2023PZ RINCON I Pz Rincon Iground waterPFOS5.3 ppt4.0 ppt
Jan 13, 2023PZ RINCON I Pz Rincon Iground waterLithium12.7 ppb9 ppb
Jul 10, 2023PZ RINCON I Pz Rincon Iground waterPFBS4.5 ppt3.0 ppt
Jul 10, 2023PZ RINCON I Pz Rincon Iground waterPFOS5.2 ppt4.0 ppt
Jul 10, 2023PZ RINCON I Pz Rincon Iground waterPFPeA4.1 ppt3.0 ppt
Jul 10, 2023PZ RINCON II (CRUCES) Pz Rincon II (Cruces)ground waterPFBS3.7 ppt3.0 ppt
Jul 10, 2023PZ RINCON II (CRUCES) Pz Rincon II (Cruces)ground waterPFHxA3.3 ppt3.0 ppt
Jul 10, 2023PZ RINCON II (CRUCES) Pz Rincon II (Cruces)ground waterPFPeA4.9 ppt3.0 ppt
Jul 10, 2023PZ RIO GRANDE I Pz Rio Grande Iground waterPFBA5.7 ppt5.0 ppt
Jul 10, 2023PZ RIO GRANDE I Pz Rio Grande Iground waterPFBS5.2 ppt3.0 ppt
Jul 10, 2023PZ RIO GRANDE I Pz Rio Grande Iground waterPFHxA4.7 ppt3.0 ppt
Jul 10, 2023PZ RIO GRANDE I Pz Rio Grande Iground waterPFOS4.8 ppt4.0 ppt
Jul 10, 2023PZ RIO GRANDE I Pz Rio Grande Iground waterPFPeA6.7 ppt3.0 ppt
Jul 11, 2023PZ PUENTE II Pz Puente IIground waterPFBS3.4 ppt3.0 ppt
Jun 25, 2025PZ RIO GRANDE II Pz Rio Grande IIground waterPFBS3.9 ppt3.0 ppt
Jun 25, 2025PZ RIO GRANDE II Pz Rio Grande IIground waterLithium23.7 ppb9 ppb
Dec 17, 2025PZ RIO GRANDE II Pz Rio Grande IIground waterPFBA7.8 ppt5.0 ppt

Utility-reported context (UCMR 5 questionnaire, aggregated across sampling events): PFAS previously found at this system: not known at 34 of 34 sampling events; potential PFAS sources nearby: not known at 34 of 34 sampling events.

Lead at customer taps

In the latest completed monitoring period, ending Dec 31, 2015, 9 in 10 sampled homes had lead at or below 6 ppb, below the 15 ppb action level that triggers utility action. None of the 12 periods on record reached it.

Action level 15 ppb015Jan 1, 1992 – Jun 30, 1992: 10 ppbJul 1, 1992 – Dec 31, 1992: 5 ppbJan 1, 1993 – Jun 30, 1993: 2 ppbJan 1, 2000 – Jun 30, 2000: 9 ppbJul 1, 2000 – Dec 31, 2000: 3 ppbJul 1, 2001 – Dec 31, 2001: 4.3 ppbJul 1, 2002 – Dec 31, 2002: 7.6 ppbJul 1, 2003 – Dec 31, 2003: 1.5 ppbJun 1, 2006 – Sep 30, 2006: 4 ppbJul 1, 2009 – Dec 31, 2009: 9 ppbJul 1, 2012 – Dec 31, 2012: 6 ppbJul 1, 2015 – Dec 31, 2015: 6 ppbJun 30, 1992Dec 31, 20156 ppb

In the most recent completed lead monitoring period, ending Dec 31, 2015, the 90th-percentile lead result at customer taps was 6 ppb, below the action level of 15 ppb (12 monitoring periods on record, none at the action level). The 90th percentile is the value that 9 in 10 sampled homes were at or below. Values are in parts per billion (ppb).

Monitoring periodMetal90th percentileAction levelStatus
Jul 1, 2015 – Dec 31, 2015Lead6 ppb15 ppbbelow the action level
Jul 1, 2012 – Dec 31, 2012Lead6 ppb15 ppbbelow the action level
Jul 1, 2009 – Dec 31, 2009Lead9 ppb15 ppbbelow the action level
Jun 1, 2006 – Sep 30, 2006Lead4 ppb15 ppbbelow the action level
Jul 1, 2003 – Dec 31, 2003Lead1.5 ppb15 ppbbelow the action level
Jul 1, 2002 – Dec 31, 2002Lead7.6 ppb15 ppbbelow the action level
Jul 1, 2001 – Dec 31, 2001Lead4.3 ppb15 ppbbelow the action level
Jul 1, 2000 – Dec 31, 2000Lead3 ppb15 ppbbelow the action level
Jan 1, 2000 – Jun 30, 2000Lead9 ppb15 ppbbelow the action level
Jan 1, 1993 – Jun 30, 1993Lead2 ppb15 ppbbelow the action level
Jul 1, 1992 – Dec 31, 1992Lead5 ppb15 ppbbelow the action level
Jan 1, 1992 – Jun 30, 1992Lead10 ppb15 ppbbelow the action level

Drinking water violations since Sep 3, 2016

EPA lists 108 violations since Sep 3, 2016. 34 are health-based, meaning a contaminant or treatment rule was not met. The other 74 concern missed monitoring, reporting or public notices.

EPA's SDWIS database lists 108 violations recorded since Sep 3, 2016: 34 health-based (a contaminant above its maximum contaminant level, a disinfectant above its maximum residual level, or a required treatment technique not met), 72 for monitoring or reporting, 2 other (public notification or consumer confidence report requirements).

Compliance periodTypeContaminant / ruleDescriptionRecordsStatus
Oct 1, 2022 – Oct 31, 2022MCL · health-basedRevised Total Coliform RuleMaximum Contaminant Level Violation, E. coli (RTCR)1 recordResolved · 1 enforcement action
Nov 1, 2020 – Nov 30, 2020TT · health-basedInterim Enhanced Surface Water Treatment RuleMonthly Turbidity Exceed (Enhanced SWTR)1 recordResolved · 2 enforcement actions
Oct 1, 2020 – Oct 31, 2020TT · health-basedInterim Enhanced Surface Water Treatment RuleMonthly Turbidity Exceed (Enhanced SWTR)2 recordsArchived · 1 enforcement action
Oct 1, 2020 – Oct 31, 2020TT · health-basedInterim Enhanced Surface Water Treatment RuleMonthly Turbidity Exceed (Enhanced SWTR)1 recordResolved · 2 enforcement actions
Jul 1, 2020 – Sep 30, 2020MCL · health-basedTotal Haloacetic Acids (Haa5) (0.062 MG/L, limit 0.060 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 3 enforcement actions
Jul 1, 2020 – Sep 30, 2020MCL · health-basedTthm (0.1 MG/L, limit 0.080 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Jun 1, 2020 – Jun 30, 2020TT · health-basedInterim Enhanced Surface Water Treatment RuleMonthly Turbidity Exceed (Enhanced SWTR)1 recordResolved · 2 enforcement actions
May 1, 2020 – May 31, 2020TT · health-basedInterim Enhanced Surface Water Treatment RuleMonthly Turbidity Exceed (Enhanced SWTR)1 recordResolved · 2 enforcement actions
Apr 1, 2020 – Jun 30, 2020MCL · health-basedTotal Haloacetic Acids (Haa5) (0.07 MG/L, limit 0.060 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Apr 1, 2020 – Jun 30, 2020MCL · health-basedTthm (0.109 MG/L, limit 0.080 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 1 enforcement action
Jan 1, 2020 – Mar 31, 2020MCL · health-basedTotal Haloacetic Acids (Haa5) (0.066 MG/L, limit 0.060 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Jan 1, 2020 – Mar 31, 2020MCL · health-basedTthm (0.082 MG/L, limit 0.080 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 1 enforcement action
Oct 1, 2019 – Dec 31, 2019MCL · health-basedTthm (0.108 MG/L, limit 0.080 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Oct 1, 2019 – Oct 31, 2019TT · health-basedInterim Enhanced Surface Water Treatment RuleSingle Turbidity Exceed (Enhanced SWTR)1 recordResolved · 3 enforcement actions
Oct 1, 2019 – Dec 31, 2019MCL · health-basedTotal Haloacetic Acids (Haa5) (0.067 MG/L, limit 0.060 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Jul 1, 2019 – Sep 30, 2019MCL · health-basedTotal Haloacetic Acids (Haa5) (0.062 MG/L, limit 0.060 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Jul 1, 2019 – Sep 30, 2019MCL · health-basedTthm (0.094 MG/L, limit 0.080 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Apr 1, 2019 – Jun 30, 2019MCL · health-basedTotal Haloacetic Acids (Haa5) (0.072 MG/L, limit 0.060 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 3 enforcement actions
Jan 1, 2019 – Mar 31, 2019MCL · health-basedTotal Haloacetic Acids (Haa5) (0.084 MG/L, limit 0.060 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Jan 1, 2019 – Mar 31, 2019MCL · health-basedTthm (0.096 MG/L, limit 0.080 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 3 enforcement actions
Oct 1, 2018 – Dec 31, 2018MCL · health-basedTthm (0.099 MG/L, limit 0.080 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Oct 1, 2018 – Dec 31, 2018MCL · health-basedTotal Haloacetic Acids (Haa5) (0.094 MG/L, limit 0.060 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Apr 1, 2018 – Jun 30, 2018MCL · health-basedTthm (0.133 MG/L, limit 0.080 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Apr 1, 2018 – Jun 30, 2018MCL · health-basedTotal Haloacetic Acids (Haa5) (0.077 MG/L, limit 0.060 mg/L)Maximum Contaminant Level Violation, Average1 recordResolved · 2 enforcement actions
Jan 1, 2018 – Mar 31, 2018TT · health-basedCarbon, TotalTreatment Technique Precursor Removal1 recordResolved · 2 enforcement actions
Show the remaining 64 violation records
Compliance periodTypeContaminant / ruleDescriptionRecordsStatus
Jan 1, 2018 – Mar 31, 2018MCL · health-basedTthmMaximum Contaminant Level Violation, Average1 recordResolved
Jan 1, 2018 – Mar 31, 2018MCL · health-basedTotal Haloacetic Acids (Haa5)Maximum Contaminant Level Violation, Average1 recordResolved
Jul 1, 2017 – Sep 30, 2017TT · health-basedCarbon, TotalTreatment Technique Precursor Removal1 recordResolved
Apr 1, 2017 – Jun 30, 2017TT · health-basedCarbon, TotalTreatment Technique Precursor Removal1 recordResolved
Jan 1, 2017 – Mar 31, 2017TT · health-basedCarbon, TotalTreatment Technique Precursor Removal1 recordResolved
Jan 1, 2017 – Mar 31, 2017MCL · health-basedTthmMaximum Contaminant Level Violation, Average1 recordResolved
Oct 1, 2016 – Dec 31, 2016MCL · health-basedTotal Haloacetic Acids (Haa5)Maximum Contaminant Level Violation, Average1 recordResolved
Oct 1, 2016 – Dec 31, 2016MCL · health-basedTthmMaximum Contaminant Level Violation, Average1 recordResolved
Jun 1, 2025 – Jun 30, 2025MRSurface Water Treatment RuleMonitoring of Treatment (SWTR-Filter)1 recordArchived
Jul 1, 2024 – Sep 30, 2024MRNitrateMonitoring, Regular3 recordsResolved
Jan 1, 2024 – Mar 31, 2024MRNitrateMonitoring, Regular2 recordsResolved
Jan 1, 2022 – Dec 31, 2022MRArsenicMonitoring, Regular1 recordResolved
Jan 1, 2022 – Dec 31, 2022MRCadmiumMonitoring, Regular1 recordResolved
Jan 1, 2022 – Dec 31, 2022MRCyanideMonitoring, Regular1 recordResolved
Jan 1, 2022 – Dec 31, 2022MRMercuryMonitoring, Regular1 recordResolved
Jan 1, 2022 – Dec 31, 2022MRThallium, TotalMonitoring, Regular1 recordResolved
Jan 1, 2022 – Dec 31, 2022MRSeleniumMonitoring, Regular1 recordResolved
Jan 1, 2022 – Dec 31, 2022MRBeryllium, TotalMonitoring, Regular1 recordResolved
Jan 1, 2022 – Dec 31, 2022MRBariumMonitoring, Regular1 recordResolved
Jan 1, 2022 – Dec 31, 2022MRAntimony, TotalMonitoring, Regular1 recordResolved
Jan 1, 2022 – Dec 31, 2022MRChromiumMonitoring, Regular1 recordResolved
Jul 1, 2020OtherConsumer Confidence RuleConsumer Confidence Report Complete Failure to Report1 recordResolved
Jul 1, 2019 – Sep 30, 2019MRTthmMonitoring, Routine (IDSE)1 recordResolved
Jul 1, 2019 – Sep 30, 2019MRTotal Haloacetic Acids (Haa5)Monitoring, Routine (IDSE)1 recordResolved
Oct 1, 2018OtherConsumer Confidence RuleConsumer Confidence Report Inadequate Reporting1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRCis-1,2-DichloroethyleneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRDichloromethaneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRP-DichlorobenzeneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRVinyl ChlorideMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MR1,1-DichloroethyleneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MR1,2-DichloroethaneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MR1,1,1-TrichloroethaneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRCarbon TetrachlorideMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MR1,2-DichloropropaneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MR1,1,2-TrichloroethaneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRBenzeneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRStyreneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRO-DichlorobenzeneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRChlorobenzeneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MR1,2,4-TrichlorobenzeneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRTetrachloroethyleneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRTrichloroethyleneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRTolueneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRXylenes, TotalMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MRTrans-1,2-DichloroethyleneMonitoring, Regular1 recordResolved
Jul 1, 2018 – Sep 30, 2018MREthylbenzeneMonitoring, Regular1 recordResolved
Aug 1, 2017 – Aug 31, 2017MRTurbidityMonitoring, Source Water (LT2)2 recordsResolved
Aug 1, 2017 – Aug 31, 2017MRE. ColiMonitoring, Source Water (LT2)2 recordsResolved
Aug 1, 2017 – Aug 31, 2017MRCryptosporidiumMonitoring, Source Water (LT2)2 recordsResolved
Jul 1, 2017 – Jul 31, 2017MRCryptosporidiumMonitoring, Source Water (LT2)2 recordsResolved
Jul 1, 2017 – Jul 31, 2017MRE. ColiMonitoring, Source Water (LT2)2 recordsResolved
Jul 1, 2017 – Jul 31, 2017MRTurbidityMonitoring, Source Water (LT2)2 recordsResolved
May 1, 2017 – May 31, 2017MRCryptosporidiumMonitoring, Source Water (LT2)2 recordsResolved
May 1, 2017 – May 31, 2017MRTurbidityMonitoring, Source Water (LT2)2 recordsResolved
May 1, 2017 – May 31, 2017MRE. ColiMonitoring, Source Water (LT2)2 recordsResolved
Apr 1, 2017 – Apr 30, 2017MRTurbidityMonitoring, Source Water (LT2)1 recordResolved
Apr 1, 2017 – Apr 30, 2017MRCryptosporidiumMonitoring, Source Water (LT2)1 recordResolved
Apr 1, 2017 – Apr 30, 2017MRE. ColiMonitoring, Source Water (LT2)1 recordResolved
Feb 1, 2017 – Feb 28, 2017MRCryptosporidiumMonitoring, Source Water (LT2)2 recordsResolved
Feb 1, 2017 – Feb 28, 2017MRE. ColiMonitoring, Source Water (LT2)2 recordsResolved
Feb 1, 2017 – Feb 28, 2017MRTurbidityMonitoring, Source Water (LT2)2 recordsResolved
Jan 1, 2017 – Jan 31, 2017MRTurbidityMonitoring, Source Water (LT2)2 recordsResolved
Jan 1, 2017 – Jan 31, 2017MRCryptosporidiumMonitoring, Source Water (LT2)2 recordsResolved
Jan 1, 2017 – Jan 31, 2017MRE. ColiMonitoring, Source Water (LT2)2 recordsResolved

Sanitary surveys and site visits

Most recent state inspection: Feb 22, 2023 (sanitary survey); 1 visit since Sep 3, 2021.

What you can do about these results

Filters certified to reduce PFOA and PFOS

EPA testing found 5 PFAS above reporting levels in this utility's water.

Look for NSF/ANSI 53 (activated carbon) or NSF/ANSI 58 (reverse osmosis) certification that names PFOA/PFOS reduction.

Filters certified for lead reduction

The most recent 90th-percentile lead result at customer taps was 6 ppb.

NSF/ANSI 53 with a lead-reduction claim, or NSF/ANSI 58 reverse osmosis. Lead comes from plumbing, so a point-of-use filter at the kitchen tap is the relevant type.

Lithium: what reduces it

Lithium reached 23.7 ppb in a single sample, at or above EPA's non-regulatory 10 ppb health reference level.

No NSF/ANSI certification claim exists for lithium. Reverse osmosis systems reduce dissolved minerals generally; we do not recommend a specific product for lithium.

ZIP codes served

Sources

Data vintage: EPA UCMR 5 occurrence data, samples collected 2023-01-03 – 2026-06-17, final release, August 2026 (file dated Aug 28, 2026); EPA SDWIS via ECHO, 2026Q2 extract (file dated Jul 9, 2026); EPA service-area boundaries v3.0; Census 2020 ZCTAs. Page generated 2026-09-03.

Keep exploring

Every record tells
part of the story.

Find a place. Read the measurements.
Understand the context.

Explore water records