EPA system CA3310038 · California
Rancho California Water District: Lithium at or above EPA's 10 ppb health reference level
highest single sample; sampled March 2023–December 2024. Source: EPA UCMR 5 final release, August 2026.
Rancho California Water District is a local-government-owned community water system in California serving about 146,147 people, matched to 4 ZIP codes.
MCL 4.0 ppt · at or above the MCL
MCL 4.0 ppt · at or above the MCL
health reference level 10 ppb · at or above the health reference level
What EPA says about what was found
- Lithium EPA's health reference level is derived from a 2008 provisional toxicity value based on effects seen at therapeutic lithium doses; EPA notes the assessment is provisional. EPA source
- PFOS EPA set the health goal (MCLG) for PFOS at zero. EPA's 2024 rule cites its health effects assessment linking PFOS exposure to certain cancers, immune and developmental effects, and changes in cholesterol. EPA source
- PFOA EPA set the health goal (MCLG) for PFOA at zero. EPA's 2024 rule cites its health effects assessment linking PFOA exposure to certain cancers, immune and developmental effects, and changes in cholesterol. EPA source
- PFHxS EPA's 2024 rule cites health effects assessments associating PFHxS with thyroid, liver and immune effects. EPA source
Quoted from EPA assessments. This site adds no health claims of its own.
PFAS and lithium: what EPA's national survey found
EPA tested this water for 30 substances and found 9. PFOA averaged 10.5 ppt where EPA's limit is 4.0 ppt, and PFOS averaged 13.5 ppt where EPA's limit is 4.0 ppt. EPA's limit applies to a running yearly average and is enforced from 2029. That PFOS result is higher than 98% of the 10,307 water systems EPA tested for it. Lithium reached 44 ppb; EPA's health reference level, which is guidance and not a limit, is 10 ppb.
Between March 2023 and December 2024, EPA's UCMR 5 program tested 2,311 samples from 38 sampling locations for 30 contaminants (29 PFAS plus lithium). 9 were detected above the reporting level in at least one sample. Averaged over a complete monitoring set, the highest sampling location for PFOA was 10.5 ppt, at or above the MCL of 4.0 ppt that applies from 2029 (highest single sample 11.0 ppt). Averaged over a complete monitoring set, the highest sampling location for PFOS was 13.5 ppt, at or above the MCL of 4.0 ppt that applies from 2029 (highest single sample 16.0 ppt). Lithium reached 44 ppb in a single sample, at or above the health reference level of 10 ppb, which is non-regulatory.
Show the 21 contaminants not detected above the reporting level
Full table: samples, detections, highest single sample, complete-set average and sampling dates for all 30 contaminants
| Contaminant | Samples | Detections | Highest single sample | Complete-set average (results used) | EPA reference | Status | Sampled |
|---|---|---|---|---|---|---|---|
| Lithium | 78 | 15 | 44 ppb | 27.3 ppb (4 of 4) | 10 ppb health reference level · compared on the highest sample | at or above the health reference level | March 2023 – December 2024 |
| PFOS | 77 | 6 | 16.0 ppt | 13.5 ppt (2 of 2) | 4.0 ppt MCL · compared on the complete-set average | at or above the MCL | March 2023 – December 2024 |
| PFOA | 77 | 8 | 11.0 ppt | 10.5 ppt (2 of 2) | 4.0 ppt MCL · compared on the complete-set average | at or above the MCL | March 2023 – December 2024 |
| PFPeA | 77 | 4 | 7.7 ppt | 7.4 ppt (2 of 2) | none set | detected; no EPA reference value | March 2023 – December 2024 |
| PFHpA | 77 | 1 | 3.3 ppt | 1.7 ppt (2 of 2) | none set | detected; no EPA reference value | March 2023 – December 2024 |
| PFHxS | 77 | 3 | 6.7 ppt | 5.9 ppt (2 of 2) | 10.0 ppt MCL (rescission proposed) · compared on the complete-set average | below the 2024 MCL (rescission proposed) | March 2023 – December 2024 |
| PFBS | 77 | 5 | 7.3 ppt | 4.3 ppt (2 of 2) | 2,000 ppt health-based water concentration · compared on the highest sample | below the health-based water concentration | March 2023 – December 2024 |
| PFHxA | 77 | 5 | 6.6 ppt | 5.3 ppt (2 of 2) | 3,000 ppt screening level · compared on the highest sample | below the screening level | March 2023 – December 2024 |
| PFBA | 77 | 4 | 7.8 ppt | 3.9 ppt (2 of 2) | 6,000 ppt screening level · compared on the highest sample | below the screening level | March 2023 – December 2024 |
| 11Cl-PF3OUdS | 77 | 0 | < 5.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| 4:2 FTS | 77 | 0 | < 3.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| 6:2 FTS | 77 | 0 | < 5.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| 8:2 FTS | 77 | 0 | < 5.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| 9Cl-PF3ONS | 77 | 0 | < 2.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| ADONA | 77 | 0 | < 3.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| HFPO-DA (GenX) | 77 | 0 | < 5.0 ppt | — | 10.0 ppt MCL (rescission proposed) · compared on the complete-set average | not detected above the reporting level | March 2023 – December 2024 |
| NEtFOSAA | 77 | 0 | < 5.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| NFDHA | 77 | 0 | < 20.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| NMeFOSAA | 77 | 0 | < 6.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| PFDA | 77 | 0 | < 3.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| PFDoA | 77 | 0 | < 3.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| PFEESA | 77 | 0 | < 3.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| PFHpS | 77 | 0 | < 3.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| PFMBA | 77 | 0 | < 3.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| PFMPA | 77 | 0 | < 4.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| PFNA | 77 | 0 | < 4.0 ppt | — | 10.0 ppt MCL (rescission proposed) · compared on the complete-set average | not detected above the reporting level | March 2023 – December 2024 |
| PFPeS | 77 | 0 | < 4.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| PFTA | 77 | 0 | < 8.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| PFTrDA | 77 | 0 | < 7.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
| PFUnA | 77 | 0 | < 2.0 ppt | — | none set | not detected above the reporting level | March 2023 – December 2024 |
Sampling-point average: mean of a location's two (ground water) or four (surface water) UCMR 5 results with non-detects counted as zero, EPA's method for comparing UCMR 5 data to the PFAS MCLs. EPA rounds to the reference value's significant digits before deciding whether an average is "greater than" an MCL (PFOA/PFOS averages count as above 4.0 ng/L only from 4.05 ng/L; lithium results count as above the 10 ppb reference only from 15 ppb). This site does not apply that rounding: "at or above" here means the measured value is numerically at or above the reference.
Every detection by sampling location (51 results)
| Date | Sampling location | Source water | Contaminant | Result | Reporting level |
|---|---|---|---|---|---|
| Mar 9, 2023 | Entry Point to Dist. System Vdc (Ammonia Station) | ground water | Lithium | 23 ppb | 9 ppb |
| Mar 14, 2023 | Entry Point to Dist. System Well #177 | ground water | Lithium | 9.2 ppb | 9 ppb |
| Mar 16, 2023 | Entry Point to Dist. System Well 130 | ground water | Lithium | 11 ppb | 9 ppb |
| Mar 16, 2023 | Well 237 Well 237 | ground water | Lithium | 17 ppb | 9 ppb |
| Mar 20, 2023 | Entry Point to Dist. System Well 119 | ground water | PFBS | 3.3 ppt | 3.0 ppt |
| Mar 20, 2023 | Entry Point to Dist. System Well 119 | ground water | PFHxA | 4.7 ppt | 3.0 ppt |
| Mar 20, 2023 | Entry Point to Dist. System Well 119 | ground water | PFPeA | 7.7 ppt | 3.0 ppt |
| Mar 20, 2023 | Entry Point to Dist. System Well 122 | ground water | PFOA | 6.6 ppt | 4.0 ppt |
| Mar 20, 2023 | Entry Point to Dist. System Well 122 | ground water | PFOS | 4.1 ppt | 4.0 ppt |
| Mar 23, 2023 | Entry Point to Dist. System Well 109 | ground water | Lithium | 13 ppb | 9 ppb |
| Mar 23, 2023 | Entry Point to Dist. System Well 164 | ground water | Lithium | 10 ppb | 9 ppb |
| Mar 23, 2023 | EM-13 Em-13 | surface water | Lithium | 44 ppb | 9 ppb |
| Mar 23, 2023 | Entry Point to Dist. System Well #102 | ground water | PFBS | 7.3 ppt | 3.0 ppt |
| Mar 23, 2023 | Entry Point to Dist. System Well #102 | ground water | PFHpA | 3.3 ppt | 3.0 ppt |
| Mar 23, 2023 | Entry Point to Dist. System Well #102 | ground water | PFHxA | 6.2 ppt | 3.0 ppt |
| Mar 23, 2023 | Entry Point to Dist. System Well #102 | ground water | PFHxS | 6.7 ppt | 3.0 ppt |
| Mar 23, 2023 | Entry Point to Dist. System Well #102 | ground water | PFOA | 11.0 ppt | 4.0 ppt |
| Mar 23, 2023 | Entry Point to Dist. System Well #102 | ground water | PFOS | 16.0 ppt | 4.0 ppt |
| Mar 23, 2023 | Entry Point to Dist. System Well #102 | ground water | PFPeA | 6.1 ppt | 3.0 ppt |
| Apr 17, 2023 | Entry Point to Dist. System Well #211 | ground water | PFBA | 5.0 ppt | 5.0 ppt |
| Apr 17, 2023 | Entry Point to Dist. System Well #211 | ground water | PFHxS | 4.5 ppt | 3.0 ppt |
| Apr 17, 2023 | Entry Point to Dist. System Well #211 | ground water | PFOA | 9.6 ppt | 4.0 ppt |
| Apr 17, 2023 | Entry Point to Dist. System Well #211 | ground water | PFOS | 13.0 ppt | 4.0 ppt |
| Apr 19, 2023 | EM-13 Em-13 | surface water | PFBA | 5.1 ppt | 5.0 ppt |
| Jun 28, 2023 | EM-13 Em-13 | surface water | Lithium | 23 ppb | 9 ppb |
| Sep 7, 2023 | Entry Point to Dist. System Well 130 | ground water | Lithium | 9.5 ppb | 9 ppb |
| Sep 7, 2023 | Entry Point to Dist. System Well 140 | ground water | Lithium | 13 ppb | 9 ppb |
| Sep 11, 2023 | EM-13 Em-13 | surface water | Lithium | 18 ppb | 9 ppb |
| Sep 12, 2023 | Entry Point to Dist. System Well 122 | ground water | PFBS | 3.3 ppt | 3.0 ppt |
| Sep 12, 2023 | Entry Point to Dist. System Well 122 | ground water | PFOA | 10.0 ppt | 4.0 ppt |
| Sep 12, 2023 | Entry Point to Dist. System Well 122 | ground water | PFOS | 8.8 ppt | 4.0 ppt |
| Sep 12, 2023 | Entry Point to Dist. System Well #177 | ground water | Lithium | 9.9 ppb | 9 ppb |
| Sep 13, 2023 | Entry Point to Dist. System Vdc (Ammonia Station) | ground water | Lithium | 16 ppb | 9 ppb |
| Sep 13, 2023 | Entry Point to Dist. System Well 119 | ground water | PFBA | 5.1 ppt | 5.0 ppt |
| Sep 13, 2023 | Entry Point to Dist. System Well 119 | ground water | PFBS | 5.2 ppt | 3.0 ppt |
| Sep 13, 2023 | Entry Point to Dist. System Well 119 | ground water | PFHxA | 5.0 ppt | 3.0 ppt |
| Sep 13, 2023 | Entry Point to Dist. System Well 119 | ground water | PFOA | 5.9 ppt | 4.0 ppt |
| Sep 13, 2023 | Entry Point to Dist. System Well 119 | ground water | PFPeA | 7.0 ppt | 3.0 ppt |
| Sep 20, 2023 | Entry Point to Dist. System Well 143 | ground water | PFBA | 7.8 ppt | 5.0 ppt |
| Sep 20, 2023 | Entry Point to Dist. System Well 143 | ground water | PFBS | 3.5 ppt | 3.0 ppt |
| Sep 20, 2023 | Entry Point to Dist. System Well 143 | ground water | PFHxA | 6.6 ppt | 3.0 ppt |
| Sep 20, 2023 | Entry Point to Dist. System Well 143 | ground water | PFOA | 7.4 ppt | 4.0 ppt |
| Sep 21, 2023 | Well 237 Well 237 | ground water | Lithium | 14 ppb | 9 ppb |
| Sep 28, 2023 | Entry Point to Dist. System Well #102 | ground water | PFHxA | 4.4 ppt | 3.0 ppt |
| Sep 28, 2023 | Entry Point to Dist. System Well #102 | ground water | PFHxS | 5.0 ppt | 3.0 ppt |
| Sep 28, 2023 | Entry Point to Dist. System Well #102 | ground water | PFOA | 10.0 ppt | 4.0 ppt |
| Sep 28, 2023 | Entry Point to Dist. System Well #102 | ground water | PFOS | 11.0 ppt | 4.0 ppt |
| Sep 28, 2023 | Entry Point to Dist. System Well #102 | ground water | PFPeA | 4.5 ppt | 3.0 ppt |
| Dec 13, 2023 | EM-13 Em-13 | surface water | Lithium | 24 ppb | 9 ppb |
| Feb 12, 2024 | Entry Point to Dist. System Well 109 | ground water | PFOA | 5.4 ppt | 4.0 ppt |
| Feb 12, 2024 | Entry Point to Dist. System Well 109 | ground water | PFOS | 8.0 ppt | 4.0 ppt |
Utility-reported context (UCMR 5 questionnaire, aggregated across sampling events): PFAS previously found at this system: yes at 80 of 80 sampling events; potential PFAS sources nearby: no at 80 of 80 sampling events; PFAS treatment in place: no PFAS treatment at 80 of 80 sampling events.
Lead at customer taps
In the latest completed monitoring period, ending Dec 31, 2025, 9 in 10 sampled homes had lead at or below 0 ppb, below the 15 ppb action level that triggers utility action. None of the 20 periods on record reached it.
In the most recent completed lead monitoring period, ending Dec 31, 2025, the 90th-percentile lead result at customer taps was 0 ppb, below the action level of 15 ppb (20 monitoring periods on record, none at the action level). The 90th percentile is the value that 9 in 10 sampled homes were at or below. Values are in parts per billion (ppb).
| Monitoring period | Metal | 90th percentile | Action level | Status |
|---|---|---|---|---|
| Jan 1, 2023 – Dec 31, 2025 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2020 – Dec 31, 2022 | Lead | 1.8 ppb | 15 ppb | below the action level |
| Jan 1, 2017 – Dec 31, 2019 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2014 – Dec 31, 2016 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2011 – Dec 31, 2013 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2008 – Dec 31, 2010 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2005 – Dec 31, 2007 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2002 – Dec 31, 2004 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2004 – Dec 31, 2004 | Lead | 5 ppb | 15 ppb | below the action level |
| Jan 1, 2001 – Dec 31, 2003 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2000 – Dec 31, 2002 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2001 – Dec 31, 2001 | Lead | 5 ppb | 15 ppb | below the action level |
Show all 20 monitoring periods on record
| Monitoring period | Metal | 90th percentile | Action level | Status |
|---|---|---|---|---|
| Jan 1, 2023 – Dec 31, 2025 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2020 – Dec 31, 2022 | Lead | 1.8 ppb | 15 ppb | below the action level |
| Jan 1, 2017 – Dec 31, 2019 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2014 – Dec 31, 2016 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2011 – Dec 31, 2013 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2008 – Dec 31, 2010 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2005 – Dec 31, 2007 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2002 – Dec 31, 2004 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2004 – Dec 31, 2004 | Lead | 5 ppb | 15 ppb | below the action level |
| Jan 1, 2001 – Dec 31, 2003 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2000 – Dec 31, 2002 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 2001 – Dec 31, 2001 | Lead | 5 ppb | 15 ppb | below the action level |
| Jan 1, 2000 – Dec 31, 2000 | Lead | 5 ppb | 15 ppb | below the action level |
| Jan 1, 1994 – Dec 31, 1996 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 1996 – Dec 31, 1996 | Lead | 5 ppb | 15 ppb | below the action level |
| Jan 1, 1993 – Dec 31, 1995 | Lead | 0 ppb | 15 ppb | below the action level |
| Jan 1, 1994 – Dec 31, 1994 | Lead | 5 ppb | 15 ppb | below the action level |
| Jan 1, 1993 – Dec 31, 1993 | Lead | 5 ppb | 15 ppb | below the action level |
| Jan 1, 1993 – Jun 30, 1993 | Lead | 2.5 ppb | 15 ppb | below the action level |
| Jul 1, 1992 – Dec 31, 1992 | Lead | 2.5 ppb | 15 ppb | below the action level |
Drinking water violations since Sep 3, 2016
EPA lists no drinking-water violations for this utility since Sep 3, 2016.
EPA's SDWIS database lists no drinking water violations for this utility since Sep 3, 2016.
None on file.
Sanitary surveys and site visits
Most recent state inspection: Dec 4, 2025 (sanitary survey); 2 visits since Sep 3, 2021.
What you can do about these results
Filters certified to reduce PFOA and PFOS
EPA testing found 8 PFAS above reporting levels in this utility's water.
Look for NSF/ANSI 53 (activated carbon) or NSF/ANSI 58 (reverse osmosis) certification that names PFOA/PFOS reduction.
Lithium: what reduces it
Lithium reached 44 ppb in a single sample, at or above EPA's non-regulatory 10 ppb health reference level.
No NSF/ANSI certification claim exists for lithium. Reverse osmosis systems reduce dissolved minerals generally; we do not recommend a specific product for lithium.
ZIP codes served
Sources
Data vintage: EPA UCMR 5 occurrence data, samples collected 2023-01-03 – 2026-06-17, final release, August 2026 (file dated Aug 28, 2026); EPA SDWIS via ECHO, 2026Q2 extract (file dated Jul 9, 2026); EPA service-area boundaries v3.0; Census 2020 ZCTAs. Page generated 2026-09-03.
- EPA ECHO detailed facility report
- EPA UCMR 5 Data Finder
- EPA service-area boundary: modeled, 154.9 sq mi