Tap Water Lookup

EPA system TX0570034 · Texas

City of Carrollton: 4 PFAS found; PFHxA up to 5.3 ppt, below the 3,000 ppt screening level

System ID TX0570034; community water system; Texas; source: purchased surface water; serves 136,170 people via 59,408 connections; status: active

In focus136,170people served, EPA registry
Public records. Clearer context.
Highest result against its EPA referencePFHxA
PFHxA: 5.3 ppt; screening level 3,000 ppt. highest single sample.5.3 pptscreening level: 3,000 ppt

highest single sample; sampled August 2024–August 2025. Source: EPA UCMR 5 final release, August 2026.

City of Carrollton is a local-government-owned community water system in Texas serving about 136,170 people, matched to 4 ZIP codes.

< 4.0 ppt
PFOA, highest complete-set average
16 samples, none above the reporting level
MCL 4.0 ppt · not detected above the reporting level
< 4.0 ppt
PFOS, highest complete-set average
16 samples, none above the reporting level
MCL 4.0 ppt · not detected above the reporting level
< 9 ppb
Lithium, highest single sample
16 samples, none above the reporting level
health reference level 10 ppb · not detected above the reporting level
4 / 29
PFAS found above the reporting level
480 results, 4 entry points
0 at or above an MCL on the average basis
0 ppb
Lead 90th percentile
period ending Dec 31, 2025
action level 15 ppb · below the action level
0
health-based violations since Sep 3, 2016
1 violation in total

What EPA says about what was found

  • PFHxA EPA's 2023 IRIS assessment for PFHxA cites developmental, liver and blood effects in animal studies. EPA source
  • PFBS EPA's 2021 PFBS toxicity assessment cites thyroid, kidney and developmental effects in animal studies. EPA source
  • PFBA EPA's 2022 IRIS assessment for PFBA cites thyroid, liver and developmental effects in animal studies. EPA source

Quoted from EPA assessments. This site adds no health claims of its own.

PFAS and lithium: what EPA's national survey found

EPA tested this water for 30 substances and found 4.

Between August 2024 and August 2025, EPA's UCMR 5 program tested 480 samples from 4 sampling locations for 30 contaminants (29 PFAS plus lithium). 4 were detected above the reporting level in at least one sample.

Result EPA comparesNot detected, shown at the reporting levelEPA reference value, at the middle of each row's scale
ContaminantResult against the EPA referenceResultStatus
PFPeAhighest single sample
5.2 ppt
detected; no EPA reference value
PFHxAhighest single sample
5.3 ppt
below the screening level
PFBShighest single sample
3.1 ppt
below the health-based water concentration
PFBAhighest single sample
8.8 ppt
below the screening level
Show the 26 contaminants not detected above the reporting level
11Cl-PF3OUdSnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
4:2 FTSnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
6:2 FTSnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
8:2 FTSnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
9Cl-PF3ONSnot detected · reporting level 2.0 ppt
< 2.0 ppt
not detected above the reporting level
ADONAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
HFPO-DA (GenX)not detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
Lithiumnot detected · reporting level 9 ppb
< 9 ppb
not detected above the reporting level
NEtFOSAAnot detected · reporting level 5.0 ppt
< 5.0 ppt
not detected above the reporting level
NFDHAnot detected · reporting level 20.0 ppt
< 20.0 ppt
not detected above the reporting level
NMeFOSAAnot detected · reporting level 6.0 ppt
< 6.0 ppt
not detected above the reporting level
PFDAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFDoAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFEESAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFHpAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFHpSnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFHxSnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFMBAnot detected · reporting level 3.0 ppt
< 3.0 ppt
not detected above the reporting level
PFMPAnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFNAnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFOAnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFOSnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFPeSnot detected · reporting level 4.0 ppt
< 4.0 ppt
not detected above the reporting level
PFTAnot detected · reporting level 8.0 ppt
< 8.0 ppt
not detected above the reporting level
PFTrDAnot detected · reporting level 7.0 ppt
< 7.0 ppt
not detected above the reporting level
PFUnAnot detected · reporting level 2.0 ppt
< 2.0 ppt
not detected above the reporting level
Full table: samples, detections, highest single sample, complete-set average and sampling dates for all 30 contaminants
ContaminantSamplesDetectionsHighest single sampleComplete-set average (results used)EPA referenceStatusSampled
PFPeA16155.2 ppt4.3 ppt (4 of 4)none setdetected; no EPA reference valueAugust 2024 – August 2025
PFHxA16165.3 ppt4.2 ppt (4 of 4)3,000 ppt screening level · compared on the highest samplebelow the screening levelAugust 2024 – August 2025
PFBS1633.1 ppt1.5 ppt (4 of 4)2,000 ppt health-based water concentration · compared on the highest samplebelow the health-based water concentrationAugust 2024 – August 2025
PFBA16148.8 ppt7.3 ppt (4 of 4)6,000 ppt screening level · compared on the highest samplebelow the screening levelAugust 2024 – August 2025
11Cl-PF3OUdS160< 5.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
4:2 FTS160< 3.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
6:2 FTS160< 5.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
8:2 FTS160< 5.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
9Cl-PF3ONS160< 2.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
ADONA160< 3.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
HFPO-DA (GenX)160< 5.0 ppt10.0 ppt MCL (rescission proposed) · compared on the complete-set averagenot detected above the reporting levelAugust 2024 – August 2025
Lithium160< 9 ppb10 ppb health reference level · compared on the highest samplenot detected above the reporting levelAugust 2024 – August 2025
NEtFOSAA160< 5.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
NFDHA160< 20.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
NMeFOSAA160< 6.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
PFDA160< 3.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
PFDoA160< 3.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
PFEESA160< 3.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
PFHpA160< 3.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
PFHpS160< 3.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
PFHxS160< 3.0 ppt10.0 ppt MCL (rescission proposed) · compared on the complete-set averagenot detected above the reporting levelAugust 2024 – August 2025
PFMBA160< 3.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
PFMPA160< 4.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
PFNA160< 4.0 ppt10.0 ppt MCL (rescission proposed) · compared on the complete-set averagenot detected above the reporting levelAugust 2024 – August 2025
PFOA160< 4.0 ppt4.0 ppt MCL · compared on the complete-set averagenot detected above the reporting levelAugust 2024 – August 2025
PFOS160< 4.0 ppt4.0 ppt MCL · compared on the complete-set averagenot detected above the reporting levelAugust 2024 – August 2025
PFPeS160< 4.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
PFTA160< 8.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
PFTrDA160< 7.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
PFUnA160< 2.0 pptnone setnot detected above the reporting levelAugust 2024 – August 2025
UCMR 5 is a one-time national monitoring survey. Its results do not indicate compliance or non-compliance with the PFAS Maximum Contaminant Levels, which are enforced on running annual averages and take effect in 2029 (EPA has proposed allowing extensions to 2031). A single result above a limit on this page is a measurement, not a violation.

Sampling-point average: mean of a location's two (ground water) or four (surface water) UCMR 5 results with non-detects counted as zero, EPA's method for comparing UCMR 5 data to the PFAS MCLs. EPA rounds to the reference value's significant digits before deciding whether an average is "greater than" an MCL (PFOA/PFOS averages count as above 4.0 ng/L only from 4.05 ng/L; lithium results count as above the 10 ppb reference only from 15 ppb). This site does not apply that rounding: "at or above" here means the measured value is numerically at or above the reference.

Every detection by sampling location (48 results)
DateSampling locationSource waterContaminantResultReporting level
Aug 19, 2024Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFBA7.6 ppt5.0 ppt
Aug 19, 2024Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFHxA4.0 ppt3.0 ppt
Aug 19, 2024Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFPeA4.3 ppt3.0 ppt
Aug 19, 2024Jackson Vault Jackson Vaultsurface waterPFBA6.7 ppt5.0 ppt
Aug 19, 2024Jackson Vault Jackson Vaultsurface waterPFHxA3.7 ppt3.0 ppt
Aug 19, 2024Jackson Vault Jackson Vaultsurface waterPFPeA4.5 ppt3.0 ppt
Aug 19, 2024Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFBA6.5 ppt5.0 ppt
Aug 19, 2024Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFHxA4.2 ppt3.0 ppt
Aug 19, 2024Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFPeA4.4 ppt3.0 ppt
Nov 18, 2024Jackson Vault Jackson Vaultsurface waterPFBA8.0 ppt5.0 ppt
Nov 18, 2024Jackson Vault Jackson Vaultsurface waterPFHxA3.8 ppt3.0 ppt
Nov 18, 2024Jackson Vault Jackson Vaultsurface waterPFPeA3.4 ppt3.0 ppt
Nov 18, 2024Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFBA8.8 ppt5.0 ppt
Nov 18, 2024Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFHxA4.4 ppt3.0 ppt
Nov 18, 2024Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFPeA4.8 ppt3.0 ppt
Nov 18, 2024Burning Tree Vault Burning Tree Vaultsurface waterPFBA7.8 ppt5.0 ppt
Nov 18, 2024Burning Tree Vault Burning Tree Vaultsurface waterPFHxA4.1 ppt3.0 ppt
Nov 18, 2024Burning Tree Vault Burning Tree Vaultsurface waterPFPeA4.1 ppt3.0 ppt
Jan 27, 2025Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFBS3.0 ppt3.0 ppt
Jan 27, 2025Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFHxA4.9 ppt3.0 ppt
Jan 27, 2025Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFPeA4.4 ppt3.0 ppt
Feb 24, 2025Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFBS3.1 ppt3.0 ppt
Feb 24, 2025Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFHxA4.6 ppt3.0 ppt
Feb 24, 2025Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFPeA4.7 ppt3.0 ppt
May 5, 2025Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFBA6.6 ppt5.0 ppt
May 5, 2025Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFHxA3.1 ppt3.0 ppt
May 5, 2025Columbian Club Pump Station Columbian Club Pump Stationsurface waterPFPeA3.5 ppt3.0 ppt
May 5, 2025Jackson Vault Jackson Vaultsurface waterPFBA6.3 ppt5.0 ppt
May 5, 2025Jackson Vault Jackson Vaultsurface waterPFHxA3.6 ppt3.0 ppt
May 5, 2025Jackson Vault Jackson Vaultsurface waterPFPeA4.0 ppt3.0 ppt
May 5, 2025Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFBA6.7 ppt5.0 ppt
May 5, 2025Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFHxA3.5 ppt3.0 ppt
May 5, 2025Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFPeA3.8 ppt3.0 ppt
May 5, 2025Burning Tree Vault Burning Tree Vaultsurface waterPFBA6.6 ppt5.0 ppt
May 5, 2025Burning Tree Vault Burning Tree Vaultsurface waterPFHxA3.5 ppt3.0 ppt
May 5, 2025Burning Tree Vault Burning Tree Vaultsurface waterPFPeA3.8 ppt3.0 ppt
Jun 16, 2025Jackson Vault Jackson Vaultsurface waterPFBA8.0 ppt5.0 ppt
Jun 16, 2025Jackson Vault Jackson Vaultsurface waterPFBS3.0 ppt3.0 ppt
Jun 16, 2025Jackson Vault Jackson Vaultsurface waterPFHxA5.3 ppt3.0 ppt
Jun 16, 2025Jackson Vault Jackson Vaultsurface waterPFPeA5.2 ppt3.0 ppt
Jul 29, 2025Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFBA6.1 ppt5.0 ppt
Jul 29, 2025Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFHxA3.3 ppt3.0 ppt
Jul 29, 2025Bobby Ballard Pump Station Bobby Ballard Pump Stationsurface waterPFPeA3.3 ppt3.0 ppt
Jul 29, 2025Burning Tree Vault Burning Tree Vaultsurface waterPFBA5.3 ppt5.0 ppt
Jul 29, 2025Burning Tree Vault Burning Tree Vaultsurface waterPFHxA3.2 ppt3.0 ppt
Aug 25, 2025Burning Tree Vault Burning Tree Vaultsurface waterPFBA5.7 ppt5.0 ppt
Aug 25, 2025Burning Tree Vault Burning Tree Vaultsurface waterPFHxA3.8 ppt3.0 ppt
Aug 25, 2025Burning Tree Vault Burning Tree Vaultsurface waterPFPeA3.7 ppt3.0 ppt

Utility-reported context (UCMR 5 questionnaire, aggregated across sampling events): PFAS previously found at this system: no at 16 of 16 sampling events; potential PFAS sources nearby: no at 16 of 16 sampling events.

Lead at customer taps

In the latest completed monitoring period, ending Dec 31, 2025, 9 in 10 sampled homes had lead at or below 0 ppb, below the 15 ppb action level that triggers utility action. None of the 17 periods on record reached it.

Action level 15 ppb015Jan 1, 1998 – Dec 31, 2000: 4 ppbJan 1, 2001 – Dec 31, 2003: 4.2 ppbJan 1, 2004 – Dec 31, 2006: 8.9 ppbJan 1, 2005 – Dec 31, 2007: 8.9 ppbJan 1, 2007 – Dec 31, 2009: 6.1 ppbJan 1, 2008 – Dec 31, 2010: 6.1 ppbJan 1, 2010 – Dec 31, 2012: 4.7 ppbJan 1, 2011 – Dec 31, 2013: 4.7 ppbJan 1, 2014 – Dec 31, 2016: 1.5 ppbJan 1, 2017 – Dec 31, 2019: 3 ppbJan 1, 2020 – Dec 31, 2022: 0.2 ppbJan 1, 2023 – Dec 31, 2025: 0 ppbDec 31, 2000Dec 31, 20250 ppb

In the most recent completed lead monitoring period, ending Dec 31, 2025, the 90th-percentile lead result at customer taps was 0 ppb, below the action level of 15 ppb (17 monitoring periods on record, none at the action level). The 90th percentile is the value that 9 in 10 sampled homes were at or below. Values are in parts per billion (ppb).

Monitoring periodMetal90th percentileAction levelStatus
Jan 1, 2023 – Dec 31, 2025Lead0 ppb15 ppbbelow the action level
Jan 1, 2020 – Dec 31, 2022Lead0.2 ppb15 ppbbelow the action level
Jan 1, 2017 – Dec 31, 2019Lead3 ppb15 ppbbelow the action level
Jan 1, 2014 – Dec 31, 2016Lead1.5 ppb15 ppbbelow the action level
Jan 1, 2011 – Dec 31, 2013Lead4.7 ppb15 ppbbelow the action level
Jan 1, 2010 – Dec 31, 2012Lead4.7 ppb15 ppbbelow the action level
Jan 1, 2008 – Dec 31, 2010Lead6.1 ppb15 ppbbelow the action level
Jan 1, 2007 – Dec 31, 2009Lead6.1 ppb15 ppbbelow the action level
Jan 1, 2005 – Dec 31, 2007Lead8.9 ppb15 ppbbelow the action level
Jan 1, 2004 – Dec 31, 2006Lead8.9 ppb15 ppbbelow the action level
Jan 1, 2001 – Dec 31, 2003Lead4.2 ppb15 ppbbelow the action level
Jan 1, 1998 – Dec 31, 2000Lead4 ppb15 ppbbelow the action level
Show all 17 monitoring periods on record
Monitoring periodMetal90th percentileAction levelStatus
Jan 1, 2023 – Dec 31, 2025Lead0 ppb15 ppbbelow the action level
Jan 1, 2020 – Dec 31, 2022Lead0.2 ppb15 ppbbelow the action level
Jan 1, 2017 – Dec 31, 2019Lead3 ppb15 ppbbelow the action level
Jan 1, 2014 – Dec 31, 2016Lead1.5 ppb15 ppbbelow the action level
Jan 1, 2011 – Dec 31, 2013Lead4.7 ppb15 ppbbelow the action level
Jan 1, 2010 – Dec 31, 2012Lead4.7 ppb15 ppbbelow the action level
Jan 1, 2008 – Dec 31, 2010Lead6.1 ppb15 ppbbelow the action level
Jan 1, 2007 – Dec 31, 2009Lead6.1 ppb15 ppbbelow the action level
Jan 1, 2005 – Dec 31, 2007Lead8.9 ppb15 ppbbelow the action level
Jan 1, 2004 – Dec 31, 2006Lead8.9 ppb15 ppbbelow the action level
Jan 1, 2001 – Dec 31, 2003Lead4.2 ppb15 ppbbelow the action level
Jan 1, 1998 – Dec 31, 2000Lead4 ppb15 ppbbelow the action level
Jan 1, 1995 – Dec 31, 1997Lead2.4 ppb15 ppbbelow the action level
Jan 1, 1994 – Dec 31, 1994Lead3.8 ppb15 ppbbelow the action level
Jan 1, 1993 – Dec 31, 1993Lead5.4 ppb15 ppbbelow the action level
Jul 1, 1992 – Dec 31, 1992Lead3.2 ppb15 ppbbelow the action level
Jan 1, 1992 – Jun 30, 1992Lead3 ppb15 ppbbelow the action level

Drinking water violations since Sep 3, 2016

EPA lists 1 violation since Sep 3, 2016. None is health-based. All concern missed monitoring, reporting or public notices, not the water itself.

EPA's SDWIS database lists 1 violation recorded since Sep 3, 2016: 1 for monitoring or reporting, none health-based.

Compliance periodTypeContaminant / ruleDescriptionRecordsStatus
Dec 30, 2016MRLead and Copper RuleLead Consumer Notice1 recordResolved · 2 enforcement actions

Sanitary surveys and site visits

Most recent state inspection: Feb 28, 2024 (sanitary survey); 1 visit since Sep 3, 2021.

What you can do about these results

Filters certified to reduce PFOA and PFOS

EPA testing found 4 PFAS above reporting levels in this utility's water.

Look for NSF/ANSI 53 (activated carbon) or NSF/ANSI 58 (reverse osmosis) certification that names PFOA/PFOS reduction.

ZIP codes served

Sources

Data vintage: EPA UCMR 5 occurrence data, samples collected 2023-01-03 – 2026-06-17, final release, August 2026 (file dated Aug 28, 2026); EPA SDWIS via ECHO, 2026Q2 extract (file dated Jul 9, 2026); EPA service-area boundaries v3.0; Census 2020 ZCTAs. Page generated 2026-09-03.

Keep exploring

Every record tells
part of the story.

Find a place. Read the measurements.
Understand the context.

Explore water records